Low-Loss RF
Coaxial Cables
Explore six 50 Ω LMR-type cable families, from compact RF jumpers to high-performance feeders. Compare published reference loss, power, bend radius, jacket construction and operating frequency in one place.
Request datasheet or quotation →Find the right cable for your RF link.
Six cable types with different attenuation, outside diameter, routing requirements and jacket materials. Select a family for full mechanical and electrical references.
Compact routing
Compact antenna jumpers and short RF runs
Slim, lower loss
Short flexible interconnects in the 4.95 mm size class
Balanced feeder
Low-loss antenna feeders and RF distribution
Longer runs
Larger low-loss antenna feeders and longer RF links
Low loss, large OD
Large-diameter low-loss and higher-power feeders
Lowest loss to 2.5 GHz
Lowest-loss option where size and band permit
One table. Six cable families.
Use this comparison to balance the RF loss budget against installation footprint and bend-radius constraints. All values are source reference benchmarks, pending MTT-specific qualification.
| Technical parameter | RF195-FR | RF200-FR | RF400-FR | RF600-PE | RF900-FR | RF1200-FR |
|---|---|---|---|---|---|---|
| Nominal outer diameter | 4.95 mm | 4.95 mm | 10.29 mm | 14.99 mm | 22.86 mm | 30.48 mm |
| Source frequency limit | 8 GHz | 8 GHz | 8 GHz | 8 GHz | 6 GHz | 2.5 GHz |
| Jacket type | FRPE | FRPE | FRPE | PE — non-FR | FRPE | FRPE |
| Velocity of propagation | 80% | 83% | 84% | 85% | 87% | 88% |
| Install bend radius | 12.7 mm | 12.7 mm | 25.4 mm | 38.1 mm | 76.2 mm | 165.1 mm |
| Repeated-flex bend radius | 50.8 mm | 50.8 mm | 101.6 mm | 152.4 mm | 228.6 mm | 304.8 mm |
| 900 MHz attenuation | 36.5 dB/100 m | 32.6 dB/100 m | 12.8 dB/100 m | 8.2 dB/100 m | 5.6 dB/100 m | 4.2 dB/100 m |
| 900 MHz average power | 0.16 kW (reference) | 0.18 kW (reference) | 0.58 kW (reference) | 0.93 kW (reference) | 1.51 kW (reference) | 2.09 kW (reference) |
| Operating temperature | −40 to +85 °C | −40 to +85 °C | −40 to +85 °C | −40 to +85 °C | −40 to +85 °C | −40 to +85 °C |
Explore attenuation and power by frequency.
The curves connect the catalogue's published tabulated values. Each cable line stops at its own stated frequency limit.
Cable attenuation vs frequency
Typical cable-only loss at +25 °C, VSWR 1.0. Lower curves mean less attenuation at a given frequency.
Units: dB/100 m. Lines join published points for visualization only; no performance is shown beyond each model's listed limit.
Average power handling vs frequency
Source reference power values at +40 °C ambient, 100 °C inner conductor, dry air at sea level and no solar loading.
Reference kW values are not rated continuous-power guarantees for MTT production or completed connector assemblies. Consider connector ratings and temperature derating.
900 MHz quick comparison
Cable-only attenuation, dB/100 m. Lower is better.
TABLE AFull attenuation matrixPublished dB / 100 m at +25 °C+
| MHz | RF195-FR | RF200-FR | RF400-FR | RF600-PE | RF900-FR | RF1200-FR |
|---|---|---|---|---|---|---|
| 30 | 6.5 | 5.8 | 2.2 | 1.4 | 0.9 | 0.7 |
| 50 | 8.4 | 7.5 | 2.9 | 1.8 | 1.2 | 0.9 |
| 150 | 14.6 | 13.1 | 5 | 3.2 | 2.2 | 1.6 |
| 220 | 17.7 | 15.9 | 6.1 | 3.9 | 2.6 | 1.9 |
| 450 | 25.5 | 22.8 | 8.9 | 5.6 | 3.8 | 2.8 |
| 900 | 36.5 | 32.6 | 12.8 | 8.2 | 5.6 | 4.2 |
| 1,500 | 47.7 | 42.4 | 16.8 | 10.9 | 7.4 | 5.5 |
| 1,800 | 52.5 | 46.6 | 18.6 | 12.1 | 8.2 | 6.1 |
| 2,000 | 55.4 | 49.3 | 19.6 | 12.8 | 8.6 | 6.5 |
| 2,500 | 62.4 | 55.4 | 22.2 | 14.5 | 9.8 | 7.4 |
| 5,800 | 98.1 | 86.5 | 35.5 | 23.8 | 16 | — |
| 8,000 | 117.1 | 102.8 | 42.7 | 29 | — | — |
TABLE BAverage power reference matrixPublished kW by cable and frequency+
| MHz | RF195-FR | RF200-FR | RF400-FR | RF600-PE | RF900-FR | RF1200-FR |
|---|---|---|---|---|---|---|
| 30 | 0.89 | 1.02 | 3.33 | 5.51 | 8.89 | 12.63 |
| 50 | 0.68 | 0.79 | 2.57 | 4.24 | 6.85 | 9.72 |
| 150 | 0.39 | 0.45 | 1.47 | 2.41 | 3.89 | 5.54 |
| 220 | 0.32 | 0.37 | 1.2 | 1.97 | 3.19 | 4.49 |
| 450 | 0.22 | 0.26 | 0.83 | 1.35 | 2.19 | 3.06 |
| 900 | 0.16 | 0.18 | 0.58 | 0.93 | 1.51 | 2.09 |
| 1,500 | 0.12 | 0.14 | 0.44 | 0.7 | 1.14 | 1.57 |
| 1,800 | 0.11 | 0.13 | 0.4 | 0.63 | 1.03 | 1.41 |
| 2,000 | 0.1 | 0.12 | 0.37 | 0.59 | 0.97 | 1.33 |
| 2,500 | 0.09 | 0.11 | 0.33 | 0.52 | 0.86 | 1.16 |
| 5,800 | 0.06 | 0.07 | 0.21 | 0.32 | 0.52 | — |
| 8,000 | 0.04 | 0.06 | 0.17 | 0.26 | — | — |
Estimate insertion loss at your cable length.
Interactive cable-only loss calculator
Choose an MTT cable and an exact published frequency point, then enter installed cable length.
Formula: published dB/100 m × length ÷ 100. Connector loss, VSWR, temperature, installation and other uncertainties are additional. Estimates are not qualification results.
Full technical information, model by model.
Expand any model to review construction, conductor and shield dimensions, electrical parameters, environmental specifications, and the source attenuation/power table.
01MTT-RF195-FR4.95 mm OD · 8 GHz · FRPE+
Compact antenna jumpers and short RF runs. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Solid bare copper | 0.94 mm |
| Foam-PE dielectric | Foamed polyethylene | 2.79 mm |
| Aluminium outer tape | Aluminium tape | 2.95 mm |
| Overall braid | Tinned copper braid | 3.53 mm |
| Outer jacket | FRPE | 4.95 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 6.5 | 0.89 |
| 50 | 8.4 | 0.68 |
| 150 | 14.6 | 0.39 |
| 220 | 17.7 | 0.32 |
| 450 | 25.5 | 0.22 |
| 900 | 36.5 | 0.16 |
| 1,500 | 47.7 | 0.12 |
| 1,800 | 52.5 | 0.11 |
| 2,000 | 55.4 | 0.1 |
| 2,500 | 62.4 | 0.09 |
| 5,800 | 98.1 | 0.06 |
| 8,000 | 117.1 | 0.04 |
02MTT-RF200-FR4.95 mm OD · 8 GHz · FRPE+
Short flexible interconnects in the 4.95 mm size class. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Solid bare copper | 1.12 mm |
| Foam-PE dielectric | Foamed polyethylene | 2.95 mm |
| Aluminium outer tape | Aluminium tape | 3.07 mm |
| Overall braid | Tinned copper braid | 3.66 mm |
| Outer jacket | FRPE | 4.95 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 5.8 | 1.02 |
| 50 | 7.5 | 0.79 |
| 150 | 13.1 | 0.45 |
| 220 | 15.9 | 0.37 |
| 450 | 22.8 | 0.26 |
| 900 | 32.6 | 0.18 |
| 1,500 | 42.4 | 0.14 |
| 1,800 | 46.6 | 0.13 |
| 2,000 | 49.3 | 0.12 |
| 2,500 | 55.4 | 0.11 |
| 5,800 | 86.5 | 0.07 |
| 8,000 | 102.8 | 0.06 |
03MTT-RF400-FR10.29 mm OD · 8 GHz · FRPE+
Low-loss antenna feeders and RF distribution. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Solid copper-clad aluminium | 2.74 mm |
| Foam-PE dielectric | Foamed polyethylene | 7.24 mm |
| Aluminium outer tape | Aluminium tape | 7.39 mm |
| Overall braid | Tinned copper braid | 8.13 mm |
| Outer jacket | FRPE | 10.29 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 2.2 | 3.33 |
| 50 | 2.9 | 2.57 |
| 150 | 5 | 1.47 |
| 220 | 6.1 | 1.2 |
| 450 | 8.9 | 0.83 |
| 900 | 12.8 | 0.58 |
| 1,500 | 16.8 | 0.44 |
| 1,800 | 18.6 | 0.4 |
| 2,000 | 19.6 | 0.37 |
| 2,500 | 22.2 | 0.33 |
| 5,800 | 35.5 | 0.21 |
| 8,000 | 42.7 | 0.17 |
04MTT-RF600-PE14.99 mm OD · 8 GHz · PE — non-FR+
Larger low-loss antenna feeders and longer RF links. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Solid copper-clad aluminium | 4.47 mm |
| Foam-PE dielectric | Foamed polyethylene | 11.56 mm |
| Aluminium outer tape | Aluminium tape | 11.71 mm |
| Overall braid | Tinned copper braid | 12.45 mm |
| Outer jacket | PE — non-FR | 14.99 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 1.4 | 5.51 |
| 50 | 1.8 | 4.24 |
| 150 | 3.2 | 2.41 |
| 220 | 3.9 | 1.97 |
| 450 | 5.6 | 1.35 |
| 900 | 8.2 | 0.93 |
| 1,500 | 10.9 | 0.7 |
| 1,800 | 12.1 | 0.63 |
| 2,000 | 12.8 | 0.59 |
| 2,500 | 14.5 | 0.52 |
| 5,800 | 23.8 | 0.32 |
| 8,000 | 29 | 0.26 |
05MTT-RF900-FR22.86 mm OD · 6 GHz · FRPE+
Large-diameter low-loss and higher-power feeders. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Bare copper tube (5.64 mm ID) | 6.65 mm |
| Foam-PE dielectric | Foamed polyethylene | 17.27 mm |
| Aluminium outer tape | Aluminium tape | 17.42 mm |
| Overall braid | Tinned copper braid | 18.59 mm |
| Outer jacket | FRPE | 22.86 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 0.9 | 8.89 |
| 50 | 1.2 | 6.85 |
| 150 | 2.2 | 3.89 |
| 220 | 2.6 | 3.19 |
| 450 | 3.8 | 2.19 |
| 900 | 5.6 | 1.51 |
| 1,500 | 7.4 | 1.14 |
| 1,800 | 8.2 | 1.03 |
| 2,000 | 8.6 | 0.97 |
| 2,500 | 9.8 | 0.86 |
| 5,800 | 16 | 0.52 |
06MTT-RF1200-FR30.48 mm OD · 2.5 GHz · FRPE+
Lowest-loss option where size and band permit. The following performance figures are manufacturer-equivalent reference benchmarks from the supplied engineering catalogue.
Cross-section and materials
| Layer | Reference construction | Nominal OD |
|---|---|---|
| Centre conductor | Bare copper tube (7.85 mm ID) | 8.86 mm |
| Foam-PE dielectric | Foamed polyethylene | 23.37 mm |
| Aluminium outer tape | Aluminium tape | 23.52 mm |
| Overall braid | Tinned copper braid | 24.69 mm |
| Outer jacket | FRPE | 30.48 mm |
Mechanical and electrical characteristics
Published cable attenuation and average power
| Frequency (MHz) | Attenuation dB/100m | Average power kW, reference |
|---|---|---|
| 30 | 0.7 | 12.63 |
| 50 | 0.9 | 9.72 |
| 150 | 1.6 | 5.54 |
| 220 | 1.9 | 4.49 |
| 450 | 2.8 | 3.06 |
| 900 | 4.2 | 2.09 |
| 1,500 | 5.5 | 1.57 |
| 1,800 | 6.1 | 1.41 |
| 2,000 | 6.5 | 1.33 |
| 2,500 | 7.4 | 1.16 |
Build your RF interconnect to specification.
RF requirements
Specify your operating band, nominal impedance, permitted insertion loss and RF power. Evaluate performance at your installed length.
Mechanical requirements
Choose nominal OD, installation bend radius, repeated-flex requirement and outdoor/indoor deployment conditions.
Jacket & terminations
Select bulk cable or connectorized assembly. The RF600-PE option uses standard PE (not FR); any flame-retardant construction must be separately evaluated and approved.
Request a datasheet or cable quotation.