01 / Selection

Choose your MTTB cable

MTTB Series

MTTB-220

40 GHz
Published operating frequency

Cutoff: 83 GHz · 50 Ω

Enquire
MTTB Series

MTTB-360

40 GHz
Published operating frequency

Cutoff: 46 GHz · 50 Ω

Enquire
MTTB Series

MTTB-500

26.5 GHz
Published operating frequency

Cutoff: 29 GHz · 50 Ω

Enquire
MTTB Series

MTTB-800

18 GHz
Published operating frequency

Cutoff: 18 GHz · 50 Ω

Enquire
MTTB Series

MTTB-1200

10 GHz
Published operating frequency

Cutoff: 11 GHz · 50 Ω

Enquire
02 / Electrical engineering

Electrical specifications

ParameterUnitMTTB-220MTTB-360MTTB-500MTTB-800MTTB-1200
OPERATING FREQUENCYGHz404026.51810
IMPEDANCEOhm5050505050
VELOCITY OF PROPOGATION%8282838383
DIELECTRIC CONSTANT---1.491.491.451.451.45
SHIELDING EFFECTIVENESSdB> 90> 90> 90> 90> 90
TIME DELAYnS/m (nS/ft)4.06 (1.24)4.06 (1.24)4.01 (1.22)4.01 (1.22)4.01 (1.22)
CAPACITANCEpF/m (pF/ft)81.4 (24.8)81.4 (24.8)80.3 (24.5)80.3 (24.5)80.3 (24.5)
INDUCTANCEuH/m (uH/ft)0.20 (0.062)0.19 (0.058)0.18 (0.056)0.17 (0.053)0.17 (0.053)
CUTOFF FREQUENCYGHz8346291811
WITHSTAND VOLTAGEDC500900150036005000
PEAK POWERkW0.632.05.632.462.5

Operating frequency and cutoff frequency are different published parameters. Peak-power ratings are not continuous average-power ratings.

03 / RF loss

Attenuation and power handling

Published model-specific cable-only attenuation values at 25°C, in dB/100 m. Power-handling tabulation follows the source's 40°C ambient, sea-level, VSWR 1.1 reference conditions.

Attenuation comparison graph

Compare cable-only insertion loss across the published frequency range. Lower curves indicate lower loss per 100 m.

Graph uses the published attenuation table values in dB/100 m at 25°C. Curves are comparative references for cable-only loss.

Calculator uses the table value at the selected published frequency: attenuation (dB/100m) × length / 100. Connectors, mismatch and temperature effects are additional.

Show full attenuation tables (dB/100 m)
GHzMTTB-220MTTB-360MTTB-500MTTB-800MTTB-1200
0.0513.868.295.083.242.14
0.119.6511.747.194.63.04
0.544.3326.416.1710.376.93
1.063.1137.522.9614.769.95
2.090.1153.3632.6621.0714.37
4.0129.1376.146.5830.1820.92
6.0159.7593.8157.437.3226.18
8.0186.01108.9166.6443.4430.78
10.0209.5122.3574.8548.9234.95
12.0231.01134.682.3453.93—
15.0260.58151.3692.5760.81—
18.0287.72166.67101.9267.13—
24.0336.89194.22118.75——
26.5——125.2——
40.0448.0255.69———
Show power-handling reference table (kW)
GHzMTTB-220MTTB-360MTTB-500MTTB-800MTTB-1200
0.051.2342.3143.9578.24414.181
0.10.8711.6342.7945.8179.978
0.50.3860.7261.2432.5794.372
1.00.2710.5110.8751.8123.045
2.00.190.3590.6151.2692.108
4.00.1320.2520.4310.8861.448
6.00.1070.2040.350.7171.157
8.00.0920.1760.3010.6150.984
10.00.0820.1570.2680.5470.867
12.00.0740.1420.2440.496—
15.00.0660.1270.2170.44—
18.00.0590.1150.1970.398—
24.00.0510.0990.169——
26.5——0.16——
40.00.0380.075———
04 / Mechanical

Construction and mechanical data

Construction highlights

  • Silver-plated copper centre conductor
  • Low-density PTFE dielectric
  • Silver-plated flat helical outer conductor
  • Silver-plated copper shielding
  • FEP jacket

Actual layering/material selection is model dependent. Check production drawings for final construction.

Common applications

  • Military and phased-array radar
  • Electronic warfare
  • Airborne and shipboard systems
  • Precision RF interconnects

Mechanical, physical and environmental specifications

ParameterUnitMTTB-220MTTB-360MTTB-500MTTB-800MTTB-1200
CENTER CONDUCTORmm (in)0.51 (0.020)0.91 (0.036)1.45 (0.057)2.30 (0.091)3.80 (0.150)
DIELECTRICmm (in)1.37 (0.054)2.50 (0.098)4.00 (0.157)6.25 (0.246)10.40 (0.409)
OUTER CONDUCTORmm (in)1.50 (0.059)2.70 (0.106)4.30 (0.169)6.57 (0.259)10.78 (0.424)
OUTER SHIELDmm (in)1.81 (0.071)3.20 (0.126)4.76 (0.187)7.15 (0.281)11.35 (0.447)
JACKETmm (in)2.20 (0.087)3.60 (0.142)5.20 (0.205)7.80 (0.307)12.00 (0.472)
BEND RADIUS MINIMUMmm (in)15 (0.591)18 (0.709)20 (0.787)35 (1.378)60 (2.362)
BEND RADIUS REPEATEDmm (in)36 (1.42)36 (1.42)50 (1.97)80 (3.15)110 (4.33)
WEIGHTg/m (lbs/ft)18 (0.012)33 (0.022)50 (0.34)130 (0.087)280 (0.188)
TEMPERATURE RANGE°C (° F)-55 TO 165 (-67 TO 329)-55 TO 165 (-67 TO 329)-55 TO 165 (-67 TO 329)-55 TO 165 (-67 TO 329)-55 TO 165 (-67 TO 329)
05 / Custom assemblies

Connector choices and ordering

Ask MTT for cable-only lengths or connector-terminated assemblies. Refer to the model-specific connector compatibility tables in the source catalogue; final connector selection, usable frequency, assembly loss and lead time should be confirmed for the requested configuration.

Quote request should specify cable model, quantity, length, connector A, connector B, application frequency, and any special mechanical or environmental requirements.
06 / Technical enquiry

Request datasheet, pricing or samples

Your enquiry includes the MTTB Series title and selected part number.

Enquiries are submitted via FormSubmit to sales@mttinnovation.com (receiver activation required). No automatic datasheet delivery is configured.

Technical FAQs

Does the listed frequency cutoff equal the operating frequency?

No. Use the published operating frequency as the normal model rating; cutoff is a separate cable property.

Does attenuation include connector losses?

No. These are cable-only values. Completed assembly insertion loss additionally depends on connectors and mismatch.

Can I order a custom length or connector?

Yes, submit your proposed configuration for confirmation of compatibility and assembly performance.

MTT® · www.mttinnovation.com · sales@mttinnovation.com · Technical values reproduced from the supplied MTT RF Cable Solutions Word catalogue; subject to validation before contractual use.

Next
Next

LMR Series - Low-Loss RF Coaxial Cables