MTTC Series | High-Performance Semi-Flexible RF Coaxial Cables | MTT
MTT® · RF & MICROWAVE INTERCONNECTS / MTTC SERIES

High-Performance Semi-Flexible RF Coaxial Cables

Compact, shape-retaining microwave cabling for equipment interconnects

The MTTC Series combines silver-plated conductors, PTFE dielectric, and a semi-flexible outer construction for compact and repeatable microwave connections.

50 Ω3 cable modelsCable & assembly RFQs

Request datasheet / quote

MTTC Series semi-flexible coaxial cable with exposed braid, dielectric and centre conductor
01 / Selection

Choose your MTTC cable

MTTC Series

MTTC-160

26.5 GHz
Published operating frequency

Cutoff: 108 GHz · 50 Ω

Enquire
MTTC Series

MTTC-280

26.5 GHz
Published operating frequency

Cutoff: 62 GHz · 50 Ω

Enquire
MTTC Series

MTTC-400

26.5 GHz
Published operating frequency

Cutoff: 34 GHz · 50 Ω

Enquire
02 / Electrical engineering

Electrical specifications

ParameterUnitMTTC-160MTTC-280MTTC-400
OPERATING FREQUENCYGHz26.526.526.5
IMPEDANCEOhm505050
VELOCITY OF PROPOGATION%707070
DIELECTRIC CONSTANT---2.042.042.04
SHIELDING EFFECTIVENESSdB> 90> 90> 90
TIME DELAYnS/m (nS/ft)4.76 (1.45)4.76 (1.45)4.76 (1.45)
CAPACITANCEpF/m (pF/ft)95 (29)95 (29)95 (29)
INDUCTANCEuH/m (uH/ft)0.27 (0.082)0.26 (0.086)0.26 (0.086)
CUTOFF FREQUENCYGHz1086234
WITHSTAND VOLTAGEDC50010001500
PEAK POWERkW0.632.55.6

Operating frequency and cutoff frequency are different published parameters. Peak-power ratings are not continuous average-power ratings.

03 / RF loss

Attenuation and power handling

Published model-specific cable-only attenuation values at 25°C, in dB/100 m. Power-handling tabulation follows the source's 40°C ambient, sea-level, VSWR 1.1 reference conditions.

Attenuation comparison graph

Compare cable-only insertion loss across the published frequency range. Lower curves indicate lower loss per 100 m.

Graph uses the published attenuation table values in dB/100 m at 25°C. Curves are comparative references for cable-only loss.

Calculator uses the table value at the selected published frequency: attenuation (dB/100m) × length / 100. Connectors, mismatch and temperature effects are additional.

Show full attenuation tables (dB/100 m)
GHzMTTC-160MTTC-280MTTC-400
0.0525.0714.817.85
0.135.4721.0611.22
0.579.548.1926.17
1.0112.6269.338.17
3.0195.88125.0271.1
5.0253.61165.8496.22
8.0321.89216.37128.31
12.0395.66273.66165.81
15.0443.39312.2191.62
18.0486.73348.17216.09
24.0564.12414.7262.17
26.5593.6440.8280.53
Show power-handling reference table (kW)
GHzMTTC-160MTTC-280MTTC-400
0.050.1750.4671.299
0.10.1240.3290.909
0.50.0550.1440.39
1.00.0390.10.267
3.00.0220.0550.143
5.00.0170.0420.106
8.00.0140.0320.08
12.00.0110.0250.062
15.00.010.0220.053
18.00.0090.020.047
24.00.0080.0170.039
26.50.0070.0160.036
04 / Mechanical

Construction and mechanical data

Construction highlights

  • Silver-plated copper centre conductor
  • PTFE dielectric
  • Silver-plated copper tape and braid
  • Semi-flexible outer construction
  • Protective jacket

Actual layering/material selection is model dependent. Check production drawings for final construction.

Common applications

  • Board-to-board RF connections
  • Radar equipment and instruments
  • RF cabinets and test fixtures
  • Compact microwave assemblies

Mechanical, physical and environmental specifications

ParameterUnitMTTC-160MTTC-280MTTC-400
CENTER CONDUCTORmm (in)0.29 (0.011)0.51 (0.020)0.91 (0.036)
DIELECTRICmm (in)0.94 (0.037)1.63 (0.064)3.00 (0.118)
OUTER CONDUCTORmm (in)1.14 (0.045)1.79 (0.070)3.20 (0.126)
SHIELDINGmm (in)1.34 (0.053)2.16 (0.085)3.55 (0.140)
JACKETmm (in)1.60 (0.063)2.80 (0.110)4.00 (0.157)
BEND RADIUS MINIMUMmm (in)6.00 (0.236)14.00 (0.551)20.00 (0.787)
BEND RADIUS REPEATEDmm (in)16.00 (0.630)28.00 (1.100)46.00 (1.810)
WEIGHTg/m (lbs/ft)7 (0.0005)22 (0.015)49 (0.033)
TEMPERATURE RANGE°C (° F)-55 to 125 (-67 to 257)-55 to 125 (-67 to 257)-55 to 125 (-67 to 257)
05 / Custom assemblies

Connector choices and ordering

Ask MTT for cable-only lengths or connector-terminated assemblies. Refer to the model-specific connector compatibility tables in the source catalogue; final connector selection, usable frequency, assembly loss and lead time should be confirmed for the requested configuration.

Quote request should specify cable model, quantity, length, connector A, connector B, application frequency, and any special mechanical or environmental requirements.
06 / Technical enquiry

Request datasheet, pricing or samples

Your enquiry includes the MTTC Series title and selected part number.

Enquiries are submitted via FormSubmit to sales@mttinnovation.com (receiver activation required). No automatic datasheet delivery is configured.

Technical FAQs

Does the listed frequency cutoff equal the operating frequency?

No. Use the published operating frequency as the normal model rating; cutoff is a separate cable property.

Does attenuation include connector losses?

No. These are cable-only values. Completed assembly insertion loss additionally depends on connectors and mismatch.

Can I order a custom length or connector?

Yes, submit your proposed configuration for confirmation of compatibility and assembly performance.

MTT® · www.mttinnovation.com · sales@mttinnovation.com · Technical values reproduced from the supplied MTT RF Cable Solutions Word catalogue; subject to validation before contractual use.

Previous
Previous

Series A - High-performance flexible low-loss coax

Next
Next

Series D - Semi-rigid microwave coax