MTTD Series | Low-Loss Semi-Rigid Microwave Coaxial Cables | MTT
MTT® · RF & MICROWAVE INTERCONNECTS / MTTD SERIES

Low-Loss Semi-Rigid Microwave Coaxial Cables

Precision shapeable interconnects for high-frequency aerospace, radar and instrument assemblies

The MTTD Series combines a high-integrity semi-rigid outer conductor and PTFE-based dielectric construction for low loss, shielding and durable formed microwave assemblies.

50 Ω4 cable modelsCable & assembly RFQs

Request datasheet / quote

MTTD Series semi-rigid microwave cable with exposed dielectric and centre conductor
01 / Selection

Choose your MTTD cable

MTTD Series

MTTD-086

50 GHz
Published operating frequency

Cutoff: 64 GHz · 50 Ω

Enquire
MTTD Series

MTTD-120

40 GHz
Published operating frequency

Cutoff: 40 GHz · 50 Ω

Enquire
MTTD Series

MTTD-141

26.5 GHz
Published operating frequency

Cutoff: 36 GHz · 50 Ω

Enquire
MTTD Series

MTTD-141L

26.5 GHz
Published operating frequency

Cutoff: 38 GHz · 50 Ω

Enquire
02 / Electrical engineering

Electrical specifications

ParameterUnitMTTD-086MTTD-120MTTD-141MTTD-141L
OPERATING FREQUENCYGHz504026.526.5
IMPEDANCEOhm50505050
VELOCITY OF PROPOGATION%76767682
DIELECTRIC CONSTANT---1.731.731.731.49
SHIELDING EFFECTIVENESSdB> 165> 165> 165> 165
TIME DELAYnS/m (nS/ft)4.38 (1.33)4.38 (1.33)4.38 (1.33)4.06 (1.24)
CAPACITANCEpF/m (pF/ft)87.7 (26.7)87.7 (26.7)87.7 (26.7)81.4 (24.8)
INDUCTANCEuH/m (uH/ft)0.23 (0.071)0.21 (0.063)0.22 (0.066)0.21 (0.063)
CUTOFF FREQUENCYGHz64403638
WITHSTAND VOLTAGEDC600100013001300
PEAK POWERkW2.02.54.24.2

Operating frequency and cutoff frequency are different published parameters. Peak-power ratings are not continuous average-power ratings.

03 / RF loss

Attenuation and power handling

Published model-specific cable-only attenuation values at 25°C, in dB/100 m. Power-handling tabulation follows the source's 40°C ambient, sea-level, VSWR 1.1 reference conditions.

Attenuation comparison graph

Compare cable-only insertion loss across the published frequency range. Lower curves indicate lower loss per 100 m.

Graph uses the published attenuation table values in dB/100 m at 25°C. Curves are comparative references for cable-only loss.

Calculator uses the table value at the selected published frequency: attenuation (dB/100m) × length / 100. Connectors, mismatch and temperature effects are additional.

Show full attenuation tables (dB/100 m)
GHzMTTD-086MTTD-120MTTD-141MTTD-141L
0.0512.217.496.836.7
0.117.2810.619.679.49
0.538.823.8921.7821.37
1.055.0433.9530.9830.39
2.078.1948.3644.1643.3
4.0111.2769.0863.1461.88
6.0136.9385.2677.9876.4
8.0158.7499.0990.6888.82
10.0178.1111.4102.0199.89
12.0195.72122.65112.36110.0
15.0219.75138.06126.56123.87
18.0241.65152.17139.56136.56
24.0280.93177.61163.05159.47
26.5295.96187.39172.09168.28
35.0342.81218.04——
40.0368.0234.62——
Show power-handling reference table (kW)
GHzMTTD-086MTTD-120MTTD-141MTTD-141L
0.051.172.3942.6772.757
0.10.8271.691.8891.946
0.50.3680.7510.8390.864
1.00.2590.5280.590.608
2.00.1830.3710.4140.427
4.00.1280.2590.2890.298
6.00.1040.210.2340.242
8.00.090.1810.2010.208
10.00.080.1610.1790.185
12.00.0730.1460.1630.168
15.00.0650.130.1440.149
18.00.0590.1180.1310.135
24.00.0510.1010.1120.116
26.50.0480.0960.1060.11
35.00.0420.082——
40.00.0390.076——
04 / Mechanical

Construction and mechanical data

Construction highlights

  • Silver-plated copper centre conductor
  • PTFE / low-density PTFE dielectric (model-dependent)
  • Semi-rigid outer conductor
  • Formed assembly capability
  • Precision microwave connectors

Actual layering/material selection is model dependent. Check production drawings for final construction.

Common applications

  • Radar and phased-array networks
  • Microwave measurement and instrumentation
  • Airborne and defence RF modules
  • Custom pre-formed cable assemblies

Mechanical, physical and environmental specifications

ParameterUnitMTTD-086MTTD-120MTTD-141MTTD-141L
CENTER CONDUCTORmm (in)0.56 (0.022)0.91 (0.036)0.99 (0.039)1.05 (0.041)
DIELECTRICmm (in)1.68 (0.066)2.70 (0.106)3.00 (0.118)3.00 (0.118)
OUTER CONDUCTORmm (in)2.18 (0.086)3.05 (0.120)3.58 (0.141)3.58 (0.141)
BEND RADIUS MINIMUMmm (in)7 (0.276)10 (0.394)20 (0.787)12.5 (0.492)
WEIGHTg/m (lbs/ft)19 (0.013)35 (0.023)43 (0.029)45 (0.030)
TEMPERATURE RANGE°C (° F)-65 TO 250 (-85 TO 482)-65 TO 250 (-85 TO 482)-65 TO 250 (-85 TO 482)-65 TO 250 (-85 TO 482)
05 / Custom assemblies

Connector choices and ordering

Ask MTT for cable-only lengths or connector-terminated assemblies. Refer to the model-specific connector compatibility tables in the source catalogue; final connector selection, usable frequency, assembly loss and lead time should be confirmed for the requested configuration.

Quote request should specify cable model, quantity, length, connector A, connector B, application frequency, and any special mechanical or environmental requirements.
06 / Technical enquiry

Request datasheet, pricing or samples

Your enquiry includes the MTTD Series title and selected part number.

Enquiries are submitted via FormSubmit to sales@mttinnovation.com (receiver activation required). No automatic datasheet delivery is configured.

Technical FAQs

Does the listed frequency cutoff equal the operating frequency?

No. Use the published operating frequency as the normal model rating; cutoff is a separate cable property.

Does attenuation include connector losses?

No. These are cable-only values. Completed assembly insertion loss additionally depends on connectors and mismatch.

Can I order a custom length or connector?

Yes, submit your proposed configuration for confirmation of compatibility and assembly performance.

MTT® · www.mttinnovation.com · sales@mttinnovation.com · Technical values reproduced from the supplied MTT RF Cable Solutions Word catalogue; subject to validation before contractual use.

Previous
Previous

Series C - Semi-flexible coax

Next
Next

Series F - Economical, Low-Loss Flexible Coaxial Cables