MTTF Series | Economical, Low-Loss Flexible Coaxial Cables | MTT®
MTT® · RF & Microwave Cable Solutions

MTTF Series

Economical, Low-Loss Flexible Coaxial Cables

The MTTF series provides economical flexible coaxial cables with low-density PTFE tape dielectric and aluminium tape outer conductor. The catalogue positions these products for power-sensitive RF interconnection, base stations and wireless systems.

50 Ω4 cable modelsRF / microwaveCustom assemblies
Economical flexible low-loss RF coaxial cable cutaway with blue protective jacket, braided shield, dielectric and conductor (photorealistic product illustration)
Catalogue product photograph · MTTF cable family (representative)
01 / Product selection

Choose your MTTF cable model

The models differ in diameter, published operating limit, insertion loss and mechanical dimensions.

MTTF SERIES

MTTF-280

26.5 GHz

Published operating frequency

2.6 mm OD · cutoff 67 GHz

0.6 kW peak power (catalogue)

Enquire about MTTF-280
MTTF SERIES

MTTF-350

18 GHz

Published operating frequency

3.5 mm OD · cutoff 40 GHz

1.6 kW peak power (catalogue)

Enquire about MTTF-350
MTTF SERIES

MTTF-500

13.5 GHz

Published operating frequency

5.2 mm OD · cutoff 25 GHz

5.6 kW peak power (catalogue)

Enquire about MTTF-500
MTTF SERIES

MTTF-750

13.5 GHz

Published operating frequency

7.8 mm OD · cutoff 16 GHz

10 kW peak power (catalogue)

Enquire about MTTF-750
02 / Engineering specifications

Electrical performance

Model-specific specifications as recorded in the supplied MTT cable catalogue. A cutoff-frequency figure does not replace the published operating-frequency limit.

ParameterMTTF-280MTTF-350MTTF-500MTTF-750
Operating Frequency (GHz)26.51813.513.5
Impedance (Ω)50505050
Velocity Of Propogation (%)76767676
Dielectric Constant1.731.731.731.73
Shielding Effectiveness (dB)> 90> 90> 90> 90
Time Delay (ns/m (ns/ft))4.38 (1.33)4.38 (1.33)4.38 (1.33)4.38 (1.33)
Capacitance (pF/m (pF/ft))87.7 (26.7)87.7 (26.7)87.7 (26.7)87.7 (26.7)
Inductance (µH/m (µH/ft))0.22 (0.067)0.22 (0.067)0.22 (0.067)0.22 (0.067)
Cutoff Frequency (GHz)67402516
Withstand Voltage (V DC)50080015002000
Peak Power (kW)0.61.65.610
03 / Loss and power

Attenuation comparison & power handling

The charts below compare the listed cable-only attenuation and power-reference values. A curve stops where that model's published table ends; unavailable data are not extrapolated.

Insertion loss vs frequency

dB / 100 m at +25°C

Lower loss means less attenuation for the same cable length. Connector loss and mismatch are additional.

Power handling vs frequency

kW · reference at +40°C, sea level, VSWR 1.1

Power figures are cable-reference values under the published conditions; they do not establish a completed cable-assembly rating.

Compare all models at 1 GHz

ModelLoss (dB / 100 m)Operating limitOuter diameter
MTTF-28060.6726.5 GHz2.6 mm
MTTF-35038.5718 GHz3.5 mm
MTTF-50023.7913.5 GHz5.2 mm
MTTF-75015.0713.5 GHz7.8 mm

Interactive cable-only insertion-loss calculator

Select a published frequency and enter the cable length. No interpolation beyond the source frequency points.

Full cable attenuation tables — dB / 100 m
ParameterMTTF-280MTTF-350MTTF-500MTTF-750
0.05 GHz13.088.475.133.21
0.1 GHz18.5812.017.294.57
0.5 GHz42.3227.0916.6010.47
1 GHz60.6738.5723.7915.07
2 GHz87.4455.0634.2921.83
4 GHz126.9478.9049.7631.93
6 GHz158.5597.6062.1440.09
8 GHz186.08113.6472.9247.25
10 GHz211.00127.9882.6853.78
12 GHz234.07141.1291.7159.85
13.5 GHz——98.1164.18
15 GHz266.13159.17——
18 GHz295.92175.74——
24 GHz350.70———
26.5 GHz372.10———
Full power-handling reference tables — kW
ParameterMTTF-280MTTF-350MTTF-500MTTF-750
0.05 GHz0.4652.0983.5527.850
0.1 GHz0.3271.4802.5005.519
0.5 GHz0.1440.6561.0982.409
1 GHz0.1000.4610.7661.674
2 GHz0.0700.3230.5321.155
4 GHz0.0480.2250.3660.790
6 GHz0.0380.1820.2930.629
8 GHz0.0330.1560.2500.534
10 GHz0.0290.1390.2200.469
12 GHz0.0260.1260.1990.421
13.5 GHz——0.1860.393
15 GHz0.0230.112——
18 GHz0.0210.101——
24 GHz0.017———
26.5 GHz0.016———

All loss data are taken from the supplied catalogue. Attenuation is specified at +25°C; cable power-reference values are specified at +40°C ambient, sea level, VSWR 1.1.

04 / Mechanical design

Construction, dimensions & flexibility

Use the outside diameter and bend-radius figures to help select an appropriate cable model and integration envelope.

ParameterMTTF-280MTTF-350MTTF-500MTTF-750
Center Conductor0.56 mm0.94 mm1.45 mm2.30 mm
Dielectric1.60 mm2.75 mm4.30 mm6.70 mm
Outer Conductor1.68 mm2.80 mm4.38 mm6.80 mm
Outer Shield2.00 mm3.20 mm4.78 mm7.33 mm
Jacket2.60 mm3.50 mm5.20 mm7.80 mm
Bend Radius — Minimum12.00 mm14.00 mm20.00 mm32.00 mm
Bend Radius — Repeated28.00 mm35.00 mm52.00 mm78.00 mm
Weight18 g/m29 g/m60 g/m110 g/m
Temperature Range-55 TO 165 °C-55 TO 165 °C-55 TO 165 °C-55 TO 165 °C

Dimensions and temperatures follow the supplied source. Figures for the published operating-frequency range and the cutoff frequency are separate specifications.

05 / Application fit

Where MTTF cables are used

Series benefits

Economical low-loss RF interconnectionLightweight flexible cable constructionPhase-stability-oriented product familyCustom connector and length configurations

Typical applications

RF power interconnectionBase stationsEMC systemsMilitary and aerospace equipmentWireless infrastructure
06 / Custom configurations

Connector and cable assembly options

Connector combinations shown below are drawn from the source family overview. Compatibility and available termination style vary by model and must be confirmed for each RFQ.

SMA maleSMA male right angleSMP femaleN maleN femaleTNC male

Specify the cable model, connector at each end, assembly length, quantity and operating frequency. Other connector styles may be offered subject to engineering review.

07 / Request datasheet

Request a datasheet, quotation or engineering samples

Your details are forwarded to sales@mttinnovation.com through FormSubmit when the receiving email has completed FormSubmit activation. This form does not automatically deliver the PDF. Use the form only after reviewing its data-handling requirements.

Previous
Previous

Series E - Ultra-Flexible, Low-Loss & Phase-Stable Coaxial Cables

Next
Next

Series G - Low-loss flexible coax for rugged systems