1. General Specification
| Item | Specification | Test Condition / Standard |
|---|---|---|
| Rated Voltage | 28V | — |
| Operating Voltage Range | DC 18–32V | — |
| Rated Current | Rated Current: 1.3A Safety Current (Max): 2.1A |
|
| Rated Power | 31.2W (Max: 50.4W) | — |
| Rated Speed | 10000 ±10% RPM | — |
| Air Flow at Zero Static Pressure | 140.72 CFM (Min: 126.64 CFM) | Rated Voltage |
| Air Static Pressure at Zero Airflow | 47.85 mmH₂O (Min: 43.06 mmH₂O) | — |
| Noise Level | 66.2 dB-A (Max: 69.2 dB-A) |
|
| Product Type | RoHS 2.0 | — |
| Life Expectancy | 70,000 hrs at 40℃, 65% Humidity, Room Temperature | — |
| Safety Approval | CE / UL / TUV | — |
| Dielectric Strength |
5mA Max., 500VAC/min Measured between lead wire (+) and frame at 500VAC/min |
— |
| Insulation Resistance |
10MΩ, 500VDC/min Between unshackled wire and frame at 500VDC/min |
— |
| Protection Grade | IP68 | — |
| PQ Curve | — | — |
2. Main Materials/Parts Specification
| Materials / Parts | Specification | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Frame | PBT4830 / Plastic Material UL:94V-0 PBT+30GF 30%GF (Glass Fiber) | ||||||||
| Impeller | PBT4830 / Plastic Material UL:94V-0 | ||||||||
| Frame Type | Without Pillar Frame | ||||||||
| Bearing Type | Two Ball Bearings | ||||||||
| Ring Snap Ring | Stainless Steel Buckle (Plastic Buckles are Prohibited), Shaft Core (SUS420J2) Metre | ||||||||
| Lead Wire | UL1332#24# - Black, Red, Yellow, Blue Separator | ||||||||
| Connector |
Unprovoked-4P
|
||||||||
| Environmental Requirement |
|
3. The Electrical Protection Function
| Lock Protection |
|
|---|---|
| Polarity Protection | Open circuit when Vcc & GND are exchanged |
| Over Current Protection | NO |
| Fixed Constant Speed Function | NO |
| Soft Starting | When the power switch is turned on to supply current to the fan, the current is zero and starts to increase gradually until the fan has achieved its maximum speed and the rated current. |
| PWM Function | Enter a PWM duty cycle signal to control fan speed |
| Hot plug | No |
4. Environmental Specification
| Operating Temperature Range | -40°C to +85°C |
|---|---|
| Storage Temperature | -55°C to +85°C |
| Humidity |
MIL-STD 202F Method 103B
|
| Thermal Shock | MIL-STD 202F Method 107D Per MIL-STD 202F Method 107D, Condition D |
| Insulation Shock | UL: Class A |
| Packing Vibration Test | After packaging, a 3-axis (XYZ) vibration test was conducted under 3.2G load for 30 minutes - No serious damage. |
| Packing Shock Proof Test | Dropped from a height of 60 cm on 1 corner, 3 edges, and 6 faces - No serious damage. |
| Rain | Enhanced, 1 Hour Per Surface |
| Damp Heat | GJB 150.9A-2009, temperature 30°C to 60°C, 95% relative humidity, 10 days |
| Sand & Dust | Blowing Sand and Dust Test |
6.3 Speed VS PWM Control Signal (At 24V T=25°C)
| Duty Cycle (%) | 0% | 10% | 50% | 100% |
|---|---|---|---|---|
| Speed (RPM) | 0 | 600±200RPM | 6150±10%RPM | 10000±10%RPM |
7. Fan Box Lock Attached Instructions
| MOUNTING HOLE DIAMETER | SCREW SPEC | MAJOR DIAMETER [fig.(f)] | RECOMMENDED MIN. TORQUE (kgf-cm) | ||
|---|---|---|---|---|---|
| MAXIMUM | MINIMUM | FLANGE TYPE FRAME | RIB TYPE FRAME | ||
| Ø3.5 | M4 | 4.0 | 3.85 | 4.5 | 7.5 |
| Ø4.3 | M4.8 | 4.8 | 4.65 | 5.5 | 7.5 |
| Ø4.5 | M5 | 5.0 | 4.85 | 5.5 | 7.5 |